Brand Name : City
Model Number : MOX-1 MOX-2 MOX-3 MOX-4 Mox1 Mox2 Mox3 Mox4
Certification : CE
MOQ : 1pcs
Payment Terms : T/T(wire transfer), Western Union, Paypal
Delivery Time : 3-5 working days
Packaging Details : Carton
Product Name : MOX-1 MOX-2 MOX-3 MOX-4 Mox1 Mox2 Mox3 Mox4 City Technology Medical Oxygen O2 Gas Sensor Original New
Brand : City Technology
Item No . : MOX-1 MOX-2 MOX-3 MOX-4 Mox1 Mox2 Mox3 Mox4
Test Gas : % O2 Error
50% He / 50% O2 : < 1%
60% N2 O / 40% O2 : < 1%
2% Halothane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 : < 1.5%
2% Enflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 : < 1.5%
2% Isoflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 : < 1.5%
Condition : New & Original
Warranty : 90 days
Payment Method : T/T ,Paypal ,Western Union
MOX-1 MOX-2 MOX-3 MOX-4 Mox1 Mox2 Mox3 Mox4 City Technology Medical Oxygen O2 Gas Sensor Original New.
MOX-1 MOX-2 MOX-3 MOX-4 oxygen sensors are designed to monitor partial pressure of oxygen in anesthesia (excluding xenon), intensive care, neonatal incubators, and general oxygen monitors.
MOX2 sensors come with adapters that fit onto the sensor threads and are used to direct airflow to the sensor.
MOX2 Oxygen Sensor
| Test Gas | % O2 Error | 
| 50% He / 50% O2 | < 1% | 
| 60% N2 O / 40% O2 | < 1% | 
| 2% Halothane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 | < 1.5% | 
| 2% Enflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 | < 1.5% | 
| 2% Isoflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 | < 1.5% | 
MOX2 Pictures
| OEM # | MOX-2 | 
| OEM | City Technology | 
| Condition | New and original | 
| Color | White, Clear | 
| Diameter | 1.16 in | 
| Humidity | 0 to 99% | 
| Measuring Range | 0 to 100% | 
| Power Requirements | 9 to 13 mV Signal Output | 
| Response Time | 13 sec | 
| Temperature Rating | 0 to 45 Deg C | 
IMPORTANT: Connections can only be made with recommended mating parts.
Soldering to the sensor will damage it and void the warranty.
All performance data is based on cylinder gas measurements using a flow rate of 100 ml/min. Conditions were 20°C, 50% RH and 1013 mBar. For sensor performance data under other conditions, please contact City Tech.
Performance characteristics provide an overview of the performance of the sensors offered during the first 3 months. Over time, the output signal may drift below the lower limit.
Intended Use
These sensors are designed to monitor partial pressure of oxygen in anesthesia, intensive care, incubators, and general oxygen monitors.
Stabilisation time
Allow the instrument to stabilize for at least 15 minutes before calibration.
Cleaning and Disinfection
If the sensor is contaminated, it can be washed with distilled water and dried naturally. Sensors are not suitable for steam sterilization or exposure to chemicals such as ethylene oxide or hydrogen peroxide
Calibration interval
These sensors are designed to have minimal drift over their lifetime, but for maximum accuracy they should be calibrated in 100% oxygen prior to use.
FAQ :
1. Is the oxygen sensor expired?
We have expired and new date.
2.What’s your MOQ ?
Our MOQ is one piece .You can take one sample to check our quality .
3.Do you have price list or catalogue ?
As our stock is changing everyday ,it will be appreciated to check our website and send back pictures or part no to get price .
4.Can i have a discount ?
As our profit is very low ,if ordering more ,we can give you a discount .
If you have any interest in MOX-1 MOX-2 MOX-3 MOX-4 City Technology Medical Oxygen O2 gas sensor original new,feel free to contact us .Thank you .
|   | 
| MOX-1 MOX-2 MOX-3 MOX-4 Medical Oxygen O2 Gas Sensor Images | 
 TS-W-D Patient Monitor Accessories GE Ohmeda TruSignal 9 Pin Spo2 Wrap Sensor
                                                                                    
                        
                        
                        
                                                            TS-W-D Patient Monitor Accessories GE Ohmeda TruSignal 9 Pin Spo2 Wrap Sensor
                                                    
                        
                     CBL 3 Lead ECG Safety Patient Trunk Cable IEC PN M1510A Ref 989803103871 for
                                                                                    
                        
                        
                        
                                                            CBL 3 Lead ECG Safety Patient Trunk Cable IEC PN M1510A Ref 989803103871 for
                                                    
                        
                     M1024254 GE Pediatric Reusable Temperature Probes 400 Series Skin Probe 3m 10ft
                                                                                    
                        
                        
                        
                                                            M1024254 GE Pediatric Reusable Temperature Probes 400 Series Skin Probe 3m 10ft
                                                    
                        
                     2016998-001 GE Dual Reusable Temperature Adapter Cables For 400 Series 50cm 20
                                                                                    
                        
                        
                        
                                                            2016998-001 GE Dual Reusable Temperature Adapter Cables For 400 Series 50cm 20
                                                    
                        
                     11141-000 10011141-000156 Patient Monitor Accessories Black Med-tronic Lifepak
                                                                                    
                        
                        
                        
                                                            11141-000 10011141-000156 Patient Monitor Accessories Black Med-tronic Lifepak
                                                    
                        
                     REF 989803151731 Patient Monitor Accessories philip 12 Lead Limb Lead Set AAMI
                                                                                    
                        
                        
                        
                                                            REF 989803151731 Patient Monitor Accessories philip 12 Lead Limb Lead Set AAMI
                                                    
                        
                     M1868B philip Neonatal Single Patient Cuff 4.3cm 8.0cm Size #2
                                                                                    
                        
                        
                        
                                                            M1868B philip Neonatal Single Patient Cuff 4.3cm 8.0cm Size #2
                                                    
                        
                     GE TruSignal Spo2 Interconnect Cable With GE Connector REF TS-G3 LOT 26720
                                                                                    
                        
                        
                        
                                                            GE TruSignal Spo2 Interconnect Cable With GE Connector REF TS-G3 LOT 26720
                                                    
                        
                     GE Healthcare LOT 241219K REF 4201033-001 Patient Cable In Hospital
                                                                                    
                        
                        
                        
                                                            GE Healthcare LOT 241219K REF 4201033-001 Patient Cable In Hospital
                                                    
                        
                     PN 15-100-0013 Biolight BLT Reusable Spo2 Sensor 9 Pin A1418-SA203MV
                                                                                    
                        
                        
                        
                                                            PN 15-100-0013 Biolight BLT Reusable Spo2 Sensor 9 Pin A1418-SA203MV